Effect of moisture content and frequency variation on dielectric properties of bamboo (Phyllostachys heterocycla cv. pubescens)

Forest Industry  
EFFECT OF MOISTURE CONTENT AND FREQUENCY VARIATION  
ON DIELECTRIC PROPERTIES OF BAMBOO  
(Phyllostachys heterocycla cv. pubescens)  
Nguyen Thi Huong Giang1, Tran Van Chu2  
1,2Vietnam National University of Forestry  
SUMMARY  
Moisture content of bamboo and frequency are the most important factors that affects dielectric properties of  
bamboo material. Dielectric properties of bamboo is one of the most important factors to determine the high-  
frequency hot pressing process parameters of glued laminated bamboo... Therefore, study on dielectric  
properties of bamboo has important significance. Bamboo was adjusted moisture content under laboratory  
conditions for 0-18%. Effect of moisture content and frequency variation on dielectric properties of bamboo  
was determined by using the 4294A Precision Impedance Analyzer with the 16451B. Dielectric properties  
including dielectric constant (e’) and dielectric loss tangent (tan d) have been done in the moisture content  
range from 0% to 18% and in the frequency range from 60 Hz to 6 MHz. The results showed that the dielectric  
constant (e’) and tan d increase with the increasing moisture content and decrease with the increasing  
frequency. Dielectric constant and tan d increased slowly with the moisture content below fiber saturation point  
(FSP), increased sharply with the moisture content around the FSP. Dielectric constant and tan d decreased  
obviously with the frequency below 6 kHz, but changed slowly when it above 6 kHz.  
Keywords: Bamboo, dielectric constant, dielectric loss tangent, frequency, moisture content.  
Electric properties of both wood and WPC  
were measured under different moisture  
contents and relative humidities. It showed that  
dielectric constant of wood increased  
significantly with moisture content but no  
significant difference was observed in the case  
of WPC within the range of moisture contents  
studied (Khan et al., 1991).  
I. INTRODUCTION  
Bamboo is a natural material. It has been  
used traditionally as an engineering-structural  
material for fabrication of village houses in all  
stages of human culture development. In order  
to utilize bamboo effectively under modern  
scientific and technological conditions it is  
necessary to study its properties. Bamboo is a  
main material for bamboo-based panelsand a  
wide range of bamboo products, including  
bamboo articles for daily uses and bamboo  
carbon (Zhang, 1995; Zhang et al., 2001).  
Dielectric constant and dielectric loss  
tangent is important factor of the dielectric  
properties of bamboo. It has important  
implications in the high-frequency and  
microwave heating technology of bamboo  
processing applications. Applications of  
dielectric properties of bamboo and wood in  
high-frequency and microwave heating  
technology to determined drying, glueing,  
softening and moisture content of bamboo and  
wood (Yin, 1996).  
Dielectric constant and tan d values of  
different sections of bamboo cut from outer  
skin to the central core have been determined  
at different temperature range and frequency  
range (Chand et al., 2006). It has been found  
that dielectric constant and tan d increased with  
increase of temperature and decreased with  
from the center core to periphery outer surface  
with increase of frequency.  
The estimation of dielectric loss factor  
which is considered a very important feature  
for bamboo industry and wood industry,  
properties of different wood species was done  
by using soft computing algorithms as a  
function of both ambient electro-thermal  
126  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
Forest Industry  
conditions applied during drying of wood and  
basic wood chemistry (Iliadis et al., 2013).  
Dielectric constant and dielectric loss  
tangent of bamboo culm increased slowly with  
the moisture content below fiber saturation  
point (FSP), increased sharply with the  
moisture content around the FSP, and when  
above the FSP, it had a linear relation with the  
moisture content. Dielectric constant of grain  
direction was higher than that of other two  
directions. It decreased obviously with the  
increase of frequency, but changed slowly  
when it above 6 kHz. Bamboo culm age,  
different part of culm had no evident effect on  
dielectric constant (Xu et al., 2012).  
wood quite widely. However, very little work  
has been done on the dielectric properties of  
bamboo.  
This study determined dielectric constant  
and dielectric loss factor of bamboo at  
different moisture contents and frequencies.  
The main purpose is to provide the dielectric  
properties of bamboo to determine the  
parameters of high frequency press technology.  
II. RESEARCH METHODOLOGY  
2.1. Materials  
The bamboo (Phyllostachys heterocycla cv.  
pubescens) trees [6 years old, diameter ranging  
from 7 to 12 cm] were collected from  
Zhejiang, China. Approximately, the same  
amount of bamboo semicircular fragments was  
cut from the bamboo stem to prepare flat-  
rolled. Bamboo samples were cut from these  
bamboo strips with a diameter of 50 mm and  
thickness of 5 mm. Uniformity of test sample  
surfaces were polished by using a sanding  
paper. Total of test samples were 12 samples.  
2.2. Experimental methods  
Bamboo or wood-like materials such as  
WPC can be used as an important insulating  
material for special applications. All untreated  
woods had a higher dielectric constant than  
their polymer composites. It is therefore  
postulated that the presence of polymers has  
led to a decrease in the number of polarizable  
units (Chia et al., 1986).  
2.1.2. Moisture adjustment  
Dielectric properties of wood block treated  
at various temperatures up to 800°C were  
measured in the range from 20Hz to 1MHz and  
from -150 - 20°C. These results suggested that  
the electric conductivity decreased with  
increasing temperature up to 400°C and a  
small volume fraction of particles with large  
conductivity is formed at microscopic levels in  
the cell walls (Sugimoto et al., 2004).  
Moisture adjustment was conducted in  
drying cabinet. Based on experimental  
requirements, all samples were put into drying  
cabinet and the use of thermostat humidity  
cabinet to adjust moisture content of bamboo  
samples. All samples were conditioned for 0%  
to 18% relative humidity to adjust. Moisture  
adjustment times were 3 times, every time was  
3
days. Moisture content adjustment  
At present, study on dielectric properties of  
parameters of bamboo samples in Table 1.  
Table 1. Moisture content adjustment parameters of Bamboo  
Adjustment parameters  
Moisture  
content  
(%)  
Time 1  
Temperature (0C)  
Time 2  
Temperature (0C)  
20  
Humidity (%)  
0 ÷ 2  
Salt solution  
0
6
-
1002  
35  
40  
78  
98  
20  
20  
20  
KNO3  
NaCl  
MgCl2  
12  
18  
35  
35  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
127  
Forest Industry  
The moisture content (MC) of the samples  
were calculated according to the following  
formula: MC (%) = [(m1-m0)/m0]×100, where  
m1 is the weight of the sample before drying,  
and m0 is the weight of the sample  
immediately after drying.  
2.1.2. Experimentalmethod  
Figure 1 displays the flow chart when using  
the 16451B for permittivity measurements.  
Prepare the  
dielectric material  
Attach the guarded  
electrode  
Cable length  
compensation  
Connect the 16451B  
Adjust the electrodes  
Calculate permittivity  
Compensate the  
residual impedance  
Set the measurement  
conditions  
Compensation  
for adjustment  
Insert the material  
Cp-D measurement  
Figure 1. Measurement procedure flow chart for the 16451B  
When using an impedance-measuring  
instrument to measure permittivity, the parallel  
plate method is usually employed. An  
overview of the parallel plate method is shown  
in Figure 2.  
capacitor. The measured capacitance is then  
used to calculate permittivity. In an actual test  
setup, two electrodes are configured with a test  
fixture sandwiching dielectric material. The  
impedance- measuring instrument would  
measure vector components of capacitance (C)  
and dissipation (D) and a software program  
would calculate permittivity and loss tangent.  
The parallel plate method, also called the  
three terminal method in ASTM D150,  
involves sandwiching a thin sheet of material  
or liquid between two electrodes to form a  
Figure 2. Parallel plate method  
frequency range from 60 Hz to 6 MHz.  
2.1.3. Measurement of Dielectric  
The measurements of dielectric constant  
(e’) and tan (d) values of bamboo samples  
were made by using a Agilent 4294A Precision  
Impedance Analyze with the 16451B, in the  
moisture content range from 0% to 18% and  
e’ was calculated by using the following  
equations: e’ = (ta×Cp)/(A×e0), where Cp (F) is  
equivalent parallel capacitance, ta (m) is  
average thickness of test sample, A (m2) is area  
of Guarded electrode, and e0 = 8.854×10-12  
128  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
Forest Industry  
[F/m]. Each sample had tested with 3 times.  
Value of e’ and tan d were averaged.  
bamboo sample increased in the order of the  
treatment  
moisture  
contents  
(0%<6%<12%<18%). Moisture content is the  
dominating factor over duration of adjusting in  
increasing e’. The same dielectric constant can  
be obtained at lower treatment frequency with  
lower moisture content or by using higher  
treatment frequency with higher moisture  
content. For example, with the same treatment  
time were nine days, dielectric constant of  
bamboo samples were about 6.0 0.5 when  
moisture content at 6% for 60Hz but only  
required 20% at 6 MHz.  
III. RESULTS AND DISCUSSION  
3.1. Dielectric constant (e’)  
The change of dielectric constant as a  
function of moisture content at several  
frequencies for bamboo is shown in Figure 3.  
It is visible that dielectric constant of bamboo  
is directly related to treatment severity, which  
depends on the moisture content. e’ increased  
with increasing moisture content showing  
anomaly at the transition MC from 0% to 18%.  
e’ decreased with increasing frequency from  
60 Hz to 6 MHz. e’ increased with increasing  
severity of moisture content treatment. With  
the same moisture content condition, in  
general, e’ of treated bamboo sample decreased  
in the order of the frequencies from small to  
large. It is quite the reverse, with different  
moisture content conditions on the same  
bamboo sample, in general, e’ of treated  
Dielectric constant of the bamboo in the dry  
state has lowest value (2.0) and has highest  
value 2.19 with different frequency.  
Dielectric constant of the bamboo at MC  
18% has the lowest value (6.68) with  
frequency at 6 MHz and it has the highest  
value (61.34) with frequency at 60 Hz.  
70.00  
60Hz  
600Hz  
6KHz  
60KHz  
600KHz  
6MHz  
60.00  
50.00  
40.00  
30.00  
20.00  
10.00  
-
0
2
4
6
8
10  
12  
14  
16  
18  
20  
Moisture content (%)  
Figure 3. Variation of Dielectric constant e' for Bamboo at different moisture contents  
and frequencies  
Table 2 presents the two-way analysis of  
variance (ANOVA) results of the e’ of  
bamboo. Moisture content and frequency  
showed significant effects on dielectric  
constant, (P-value < 0.0001). In addition, these  
two factors showed significant interaction on  
the dielectric constant of bamboo.  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
129  
Forest Industry  
Table 2. Two-Factor Without Replication results of dielectric constant of bamboo  
Source  
f
MC  
df  
5
3
F-value  
42.70  
158.29  
13.66  
P-value  
< 0.0001  
< 0.0001  
< 0.0001  
f×MC  
15  
f – Frequency.  
MC – Moisture content.  
f×MC – Interaction of frequency and moisture content.  
bamboo is near the fiber saturation point, the  
movement speed of molecules bamboo is  
faster, the electrical conductivity increased to  
make dielectric constant increased. At lower  
frequencies, because the water molecules's  
dipolar are absorbed, lead to e’ values in the  
bamboo is high.  
This increase of e’ is due to the increased  
mobility of water dipoles in bamboo. Water  
has OH molecules and OH of water acts as a  
dipole (Chand et al., 1994). These dipoles  
contribute to the e’ behaviour of the bamboo.  
The bound water content of bamboo gradually  
increased when the moisture content of  
bamboo increased, e’of water is relatively high  
(81) (Liu et al., 2004), lead to e’ increases  
with increasing of water in bamboo. When  
moisture content of bamboo is lower than the  
fiber saturation point, the bound water of  
bamboo fibers has not been in a saturated state.  
Therefore, freedom degree of functional  
groups in bamboo molecules are quite small,  
kinetic energy of molecule is small that effect  
the electrical conductivity, the dielectric  
constant increases quite slowly. Dielectric  
constant decreased when moisture content is  
lower than 6% with frequency variation and  
which increased quickly when moisture  
content is larger than 12% with high frequency  
3.2. Dielectric loss tangent d  
The change of tan d value is shown in  
Figure 4. It is visible that dielectric loss  
tangent of bamboo was observed increasing  
with increasing moisture constant and  
decreasing with increasing frequency. Tan d  
decreased when moisture content is lower than  
6% and increased quickly when moisture  
content is larger than 12%. Tan d increased  
slowly with the moisture content below fiber  
saturation point (FSP), increased sharply with  
the moisture content around the FSP. Tan d  
decreased sharply at the low frequency (< 6  
KHz) and decreased slowly at the high  
frequency (> 6 KHz).  
value (> 6 KHz). The moisture content of  
2.70  
60Hz  
600Hz  
6KHz  
6MHz  
60KHz  
600KHz  
2.40  
2.10  
1.80  
1.50  
1.20  
0.90  
0.60  
0.30  
-
0
2
4
6
8
10  
12  
14  
16  
18  
20  
Moisture content (%)  
Figure 4. Variation of Dielectric loss tangent d for Bamboo sample at different moisture contents  
and frequencies  
130  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
Forest Industry  
Table 3 presents the two-way analysis of  
variance (ANOVA) results of the tan d of  
bamboo. Moisture content and frequency  
showed significant effects on dielectric loss  
tangent (P-value < 0.0001<). In addition, these  
two factors showed significant interaction on  
the dielectric loss tangent of bamboo.  
Table 3. Two-Factor Without Replication results of dielectric loss tangent of bamboo  
Source  
f
df  
5
F-value  
14.85  
37.60  
5.69  
P-value  
< 0.0001  
< 0.0001  
< 0.0001  
MC  
3
f×MC  
15  
f – Frequency.  
MC – Moisture content.  
f×MC – Interaction of frequency and moisture content.  
bamboo. Low moisture content (MC < 6%)  
and high frequency variation (> 6 KHz) are  
less effective on dielectric properties, but they  
are very effective on dielectric properties a  
thigh moisture content (MC > 12%) and low  
frequency variation (<6 KHz). Dielectric  
constant was small when the bamboo in the dry  
state with different frequency value. Dielectric  
constant of the bamboo at MC 18% was lowest  
value (6.68) with frequency at 6 MHz and it  
was highest value (61.34) with frequency at 60  
Hz. Tan d decreased when moisture content is  
lower than 6% and increased quickly when  
moisture content is larger than 12%.  
This decrease of tan d is mainly due to the  
reduction of the hydroxyl group content in  
bamboo. At lower frequency, a section of  
water molecules and free radicals in molecular  
organization of bamboo moved and actived  
when the electric current changes, tan d  
decreased sharply. Water molecules and free  
radicals in molecular organization of bamboo  
moving speed to late to keep up with changing  
frequency, the number of actived free radicals  
are reduced, conduction of electric current  
inside bamboo decrease, tan d decreased  
slowly. The lossy dielectric can be represented  
by the circuit analog of a resistance in parallel  
with a capacitor minimizes (Goodman et al.,  
1991). At higher frequencies, the capacitor  
offers low reactance minimizes the conduction  
losses in the resistor. Hence, value of dielectric  
loss decreases at the higher frequencies  
(Vijendra Lingwal et al., 2003; Shiraneet al.,  
1954). The tan d decrease from at all  
frequencies.  
(2) Dielectric constant (e’) and tan d  
increased with the increase of moisture content  
and decreased with the increase of frequency.  
Dielectric constant (e’) and tan d increased  
slowly with the moisture content below fiber  
saturation point (FSP) and they increased  
sharply with the moisture content around the  
FSP.  
(3) Dielectric constant (e’) and tan d  
changed obviously when the frequency is  
changing, and decreased with increasing  
frequency. At lower frequency, tan d decreased  
sharply. At higher frequency, tan d decreased  
slowly. Dielectric constant and tan d decreased  
obviously with the frequency below 6 KHz, but  
they changed slowly when it is above 6 KHz.  
IV. CONCLUSIONS  
Dielectric properties that include dielectric  
constant (e’) and dielectric loss tangent (tan d)  
have been done in the moisture content range  
from 0% to 18% and in the frequency range  
from 60 Hz to 6 MHz. From the above results,  
we can give some conclusions:  
(1) Dielectric constant (e’) and tan d exist in  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
131  
Forest Industry  
32(6), 18-21.  
8. Chia, L.H.L., Chua, P.H., Hon, Y.S., and Lee, E.  
REFERENCES  
1. Zhang, Q. S. (1995). Industrial utilization of  
bamboo in China (in Chinese). China Forestry  
Publishing House, Beijing.  
(1986). A preliminary study on the dielectric constant of  
WPC based on some tropical woods. Int. J. Radiation  
Applications and Instrumentation C Radiation Phys.  
Chem, 27, 207-210.  
2. Zhang, Q.S., Jiang, S.X., and Tang, Y.Y. (2001).  
Industrial utilization on bamboo (in Chinese).  
International network for bamboo and rattan, Beijing.  
3. Yin, S.C. (1996). Wood Science (in Chinese).  
China Forestry Publishing House, Beijing.  
9. Sugimoto, H., and Norimoto, M. (2004).  
Dielectric relaxation due to interfacial polarization for  
heat-treated wood. Carbon, 42, 211-218.  
10. Chand, N., and Joshi, S. K. (1994). Temperature  
dependence of dielectric behaviour of sisal fibre. J.  
Mater. Sci. Lett, 13, 156-158.  
4. Khan, M.A., Blriss, K.M., and Wang, W. (1991).  
Electrical properties and X-ray diffraction of wood and  
wood plastic composite (WPC). Int. J. Radiation  
Applications and Instrumentation C Radiation Phys.  
Chem, 38, 303-306.  
11. Liu, Y. X., and Zhao, G.J. (2004). Wood  
Resource Materials Science. China Forestry Publishing  
House, Beijing, China.  
5. Chand, N., Jain, D., and Nigrawal, A. (2006).  
Investigation on Gradient Dielectriec Characteristics of  
Bamboo (Dentroclamusstrictus). J. App.Polym. Sci. 102,  
380-386.  
12. Goodman, G., Buchanan, R.C., and Reynolds,  
T.G. (1991). In Ceramic Materials for electronics;  
Processing, properties, and applications(ed.). Buchanan,  
R. C. , Marcel Dekker, New York, pp. 32.  
6. Iliadis, L., Tachos, S., Avramidis, S., and  
Mansfield (2013). Hybrid e-regression and validation  
soft computing techniques: The case of wood dielectric  
loss factor. Neurocomputing,107 (1), 33-39.  
13. Shirane, G., Newnham,R., and Pepinsky, R.  
(1954). Dielectric properties and phase transitions of  
NaNbO3 and (Na,K)NbO3. Phys. Rev, 96, 581-588.  
14. Lingwal, V., Semwal, B.S., and Panwar, N.S.  
(2003). Dielectric properties of Na1-xKxNbO3 in  
orthorhombic phase. Bull. Mater. Sci. 26(6), 619-625.  
7. Xu, S.K., Tang, Y., Zhang, W.G., Yu, X.F., Pan,  
E.Q., and Li, Y.J. (2012). Study on Dielectric  
Properties of Bamboo Culm. J. Zhejiang. Sci. technol.  
ẢNH HƯỞNG CỦA ĐỘ ẨM VÀ TẦN SỐ ĐẾN ĐẶC TÍNH ĐIỆN MÔI  
CỦA TRE (Phyllostachys heterocycla cv. pubescens)  
Nguyễn Thị Hương Giang1, Trần Văn Chứ2  
1,2 Trường Đại học Lâm nghiệp  
TÓM TẮT  
Độ ẩm của tre và giá trị tần số là những nhân tố quan trọng nhất ảnh hưởng đến đặc tính điện môi của tre. Đặc  
tính điện môi lại là một trong những nhân tố quan trọng nhất dùng để xác định các thông số công nghệ của quá  
trình ép nhiệt cao tần ván ghép khối tre. Vì vậy, việc nghiên cứu đặc tính điện môi của tre có ý nghĩa vô cùng  
quan trọng... Trong bài viết này, độ ẩm của nguyên liệu tre được điều chỉnh từ 0 - 18% trong điều kiện phòng  
thí nghiệm. Sau đó sử dụng thiết bị 4294A kết nối với máy phân tích trở kháng 16451B để xác định ảnh hưởng  
của độ ẩm và tần số đến đặc tính điện môi của tre. Đặc tính điện môi bao gồm hằng số điện môi (e’) và góc tổn  
thất điện môi (tan d) được xác định trong phạm vi độ ẩm từ 0 - 18% và tần số từ 60 Hz - 6 MHz. Kết quả  
nghiên cứu cho thấy, hằng số điện môi (e’) và góc tổn thất điện môi (tan d) tăng khi độ ẩm của tre tăng và giảm  
khi tần số tăng. Hằng số điện môi (e’) và góc tổn thất điện môi (tan d) tăng chậm khi độ ẩm dưới điểm bão hòa  
thớ gỗ (FSP), tăng mạng khi độ ẩm tre gần với điểm bão hòa thớ gỗ FSP. Hằng số điện môi (e’) và góc tổn thất  
điện môi (tan d) không tăng rõ ràng khi tần số ở dưới 6 KHz, nhưng lại thay đổi chậm khi tần số trên 6 KHz.  
Từ khóa: Độ ẩm, góc tổn thất điện môi, hằng số điện môi, tần số, Tre.  
Received  
Revised  
Accepted  
: 05/8/2017  
: 24/9/2017  
: 05/10/2017  
132  
JOURNAL OF FORESTRY SCIENCE AND TECHNOLOGY NO. 5 - 2017  
pdf 7 trang yennguyen 16080 Free
Bạn đang xem tài liệu "Effect of moisture content and frequency variation on dielectric properties of bamboo (Phyllostachys heterocycla cv. pubescens)", để tải tài liệu gốc về máy hãy click vào nút Download ở trên

File đính kèm:

  • pdfeffect_of_moisture_content_and_frequency_variation_on_dielec.pdf