Evaluation of slip ratio correlations in two-phase flow

Nuclear Science and Technology, Vol.10, No. 1 (2020), pp. 21-30  
Evaluation of slip ratio correlations in two-phase flow  
Thanh Tram Tran1,2,3, Hyun-Sik Park2,3  
1Nuclear Training Center, 140 Nguyen Tuan str. Thanh Xuan, Ha Noi, Viet Nam  
2University of Science and Technology, 217 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Korea  
3Korea Atomic Energy Research Institute,  
111 Daedeok-daero 989, Yuseong-gu, Daejeon 34057, Republic of Korea  
(Received 19 November 2019, accepted 25 February 2020)  
Abstract: Critical flow is one of the essential parameters in LOCA accident analysis in which  
pressure difference is very high. Void fraction (α), in another term, slip ratio, s, is the key parameter  
that could affect critical flow prediction. Henry-Fauske (HF) model is the model for critical flow  
calculation existing in current computer codes such as MARS, RELAP, TRACE. However, the  
limitation of this model is slip ratio s=1. By modified the slip ratio correlation, the paper focuses on  
evaluating the HF model. Among the chosen correlations for slip ratio, Smith correlation is the best  
option for this purpose. The results in our paper showed that while the original Smith correlation with  
k=0.4 is suggested for horizontal tests, the modified one with k=0.2 could be applied for vertical tests.  
Keywords: Void fraction, slip ratio, critical flow.  
one  
component  
steam-water  
system.  
I. INTRODUCTION  
Furthermore, based on the assumption of the  
HF model, it could be applied to a well-mixed  
condition, thermal equilibrium. TR model,  
however, is applied to the two-component  
system, air-water. Together with this, to predict  
the critical mass flow, the HF model uses the  
upstream conditions, while the TR model bases  
on the throat conditions [5]. These models used  
a void fraction to predict the critical flow. Void  
fraction, defining as the fractional occupied  
area of the gas phase, is one important  
parameter for two-phase flow, based on which  
the component pressures, flow rate, and heat  
transfer are determined. Because the gas phase  
normally moves faster than that of the liquid  
phase, the void fraction could not be directly  
calculated from the mass flow rates of each  
phase separately. Therefore, void fraction  
depends on the phase velocity ratio, so-called  
slip ratio. Slip ratio can be influenced by many  
variables, such as mixture quality, temperature  
The critical flow phenomenon takes  
place when liquid, gas, or mixture leaks from a  
system at high pressure to the ambient at lower  
pressure through a break such as in a break of  
safety valves or safety injection lines during a  
loss  
of  
coolant  
accident  
(LOCA).  
Understanding of break flow and its modeling  
are important things in a LOCA scenario.  
When the system approaches the critical flow  
condition, the discharge flow through the  
broken exit could reach a maximum value, and  
the flow rate becomes independent from the  
downstream pressure. Henry-Fauske (HF) [1]  
and Trapp-Ransom (TR) [2] are two leading  
applicable models for critical flow calculation  
in the current safety analysis codes among  
many models [3], [4]. However, as the  
application of these models is different, they  
should be used carefully while doing the  
calculation. HF model is only applicable for  
©2020 Vietnam Atomic Energy Society and Vietnam Atomic Energy Institute  
EVALUATION OF SLIP RATIO CORRELATIONS IN TWO-PHASE FLOW  
and pressure, the direction of flow, circulation  
- No mass transfer in the expansion  
- Being in thermal equilibrium  
- Isentropic expansion (sg=sl)  
- The same liquid temperature.  
- Polytropic expansion of vapor at the  
mode, wall friction Fauske [1], and the system  
geometry Kim [6]. Among those affected  
parameters, Kim [6] has suggested that the  
effect of diameter was the most important one  
influencing the critical flow. His explanation  
for this effect was related to the slip ratio.  
exit (as the ideal gas).  
- The critical mass flow rate reaches a  
maximum value concerning the throat pressure,  
dG/dpt =0.  
This paper first reproduced the HF  
numerically. Our reproduced model for HF  
showed a good agreement in comparison  
with the selected database. Furthermore,  
based on Kim’s suggestion, various slip ratio  
correlations were taken into account for  
evaluating the critical flow rate. However,  
the model of HF has only considered the slip  
ratio is unity. Therefore, our focus is on  
evaluated the HF model with different slip  
ratio correlations. Our result showed that  
Smith [7] correlation was the best candidate  
for predicting the critical flow. Based on his  
original k =0.4 value, the author modified  
this value. It could conclude that among  
chosen slip correlations, Smith correlation  
gave a good agreement while varying the k  
parameter for both horizontal and vertical  
tests. While the original Smith correlation  
could be used for the horizontal test, the  
modified k=0.2 for this correlation could be  
applied for a vertical one.  
Based on these approximations, the flow  
rate can be determined as follows:  
 
 
   
    
 
   
  [  
     
   
   
 
 
           
 
   
      {  
   
         
   
   
   
 
 
    (   )  
     
 
 
 
}]  
    
          
   
   
Integrating the momentum equation  
from the stagnant to the throat locations:  
    
 
 
 
 
 
 
                
(          )  
          
 
   
 
      
 
 
 
[               ]  
 
   
     
 
 
 
   
    
 
II. HENRY-FAUSKE CORRELATION  
A. Henry-Fauske correlation  
Substitution eq. (1) into the eq. (2) and  
then rearrange this equation, the compact form  
can be obtained:  
Henry-Fauske [1] suggested the model  
for a non-equilibrium model, using two  
continuity and one momentum equations of the  
single component flow (water–vapor system)  
without considering the wall shear stress and  
heat exchange. This model also developed  
using the following approximations:  
 
    
 
 
      
 
 
 
 
 
[
 
 
 
]
 
 
        
 
      
 
    
    
 
    
 
 
 
      
 
Where:  
 
 
    
    
- Same phase velocity (k=1)  
 
 
22  
THANH TRAM TRAN, HYUN-SIK PARK  
    
            
       
data at low pressure. It means that this model  
in the current MARS code could be useful for  
high-pressure systems.  
 
 
   
      (    ) (  
)
 
 
   
   
  (      )  
 
   
   
 
 
 
(   )  
   
 
 
 
    
(      )  
   
   
and  
    
 
   
    
 
,
 
 
   
              
 
 
   
    
 
   
    
 
a   
 
 
   
              
 
 
   
 
 
 
    
 
 
   
    
   
Fig. 1. Comparison of reproducing HF model with  
For the given stagnant conditions of P0  
experimental data at 0.12MPa (17.6 psi) [1].  
and x0, by iteration until the η values in two  
Eq. (3) and Eq. (4) are converged, the critical  
pressure,   , can be obtained. The critical mass  
 
flow rate can finally be calculated.  
B. Comparison of HF model  
The main author’s difficulty is that the  
MARS code is not commercial software. It is  
only allowable for Korean students to use its  
source code. Therefore, to modify the  
correlations in the HF model, the author has  
numerically reproduced this model based on  
the main equations given in the original papers  
[1] and compared the results with original ones.  
This work can be seen in detail in our paper [5].  
Comparisons have been made for one  
component, steam-water. The critical mass flux  
data versus stagnation quality are taken from  
Fig. 2. Comparison of reproducing HF model with  
experimental data at 1.38MPa (200 psi) [1].  
HF [1] at different pressures.  
Figs.  
1, 2 and 3 show the comparisons between  
reproducing the HF model and the  
experimental data [1]. We found that this  
reproducing model gives similar results to the  
original ones.  
Fig. 3. Comparison of reproducing HF model with  
experimental data at 2.76 MPa (400 psi) [1].  
III. SLIP RATIO CORRELATIONS  
From Figs. 1, 2, and 3, one can see that  
the HF model tends to be better at high  
pressure, and its result is under-predicted the  
The  
estimation  
of  
hydrostatic,  
acceleration and friction pressure drops, and  
23  
EVALUATION OF SLIP RATIO CORRELATIONS IN TWO-PHASE FLOW  
 
critical mass flow rate in the two-phase  
mixture is based on the knowledge of the  
void fraction, the relative volumes of gas and  
liquid phases at a given location. A huge  
number of empirical correlations and  
theoretical models for void fraction have  
been proposed in the past [8], [9]. The  
theoretical ones are mainly based on  
simplifying assumptions [1], [2], respect to  
the flow regime, and therefore the results  
cannot be of general applicability to two-  
phase phenomena such as boiling process  
including several different flow regimes,  
from bubbly to separate flow. Other models  
are developed based on a limited range of  
experimental conditions such as pressure,  
temperature or quality [7], [1], [10]. The void  
fraction depends on the phase velocity ratio,  
slip ratio in the general form [8], [9] as a  
function of quality (x), density (ρ), and  
viscosity (µ):  
    
    
or  
 
)
 
 
 
    
 
 
   (  
) (  
 
 
    
 
 
 
      
 
      (  
) ( )  
 
Where the slip ratio, s, is determined  
as follows:  
    
    
 
      
      (  
 
)
(
)
    
 
 
 
Select the void fraction correlations  
having the form in Eq. (7), the author has  
compared them with the available experimental  
data (Table I).  
Void fraction correlations related to slip  
ratio are listed in Table II.  
Where: Re and We are Reynolds and  
Weber numbers, D is the equivalent diameter.  
APRM, APA and M parameters are determined as  
followings:  
 
 
 
    
    
 
        {  
     },  
    
 
 
 
)
 
 
 
 
       
      
 
 
 
 
 
      (  
) ( ) (  
 
 
       
)
 
 
      
 
 
 
             
 
(
,
 
 
In reality, only several types of  
   
   
 
      
reactors for gas/liquid exist. Moreover, one  
could be noted that the contribution of the  
 
      
 
 
 
                
,     (  
)
( ) ,  
 
 
 
 
 
 
viscosity component as shown in Table I,  
   
    
 
 
 
 
   
,      
,           a        
 
 
 
 
   
 
 
 
( ) , is less dominant. Therefore, this  
 
 
 
 
    
    1+log( )  log( ) ,  
 
 
 
parameter could be negligible in the void  
fraction form. Void fraction correlations then  
could be reduced as follows:  
 
 
 
      
          
 
   , σ is surface  
 
 
   
 
   
tension.  
Table I. References related void fraction data measurement.  
Reference  
Marchettere[11]  
Cook [12]  
Diameter[mm] Working fluid  
Geometry  
Pressure [psi]  
114 - 600  
127  
127  
Steam-Water  
Steam-Water  
Steam-Water  
Rectangular, vertical  
Rectangular, vertical  
Pipe, horizontal  
114 - 600  
Haywood [13]  
12.7-38.1  
250 - 2100  
24  
THANH TRAM TRAN, HYUN-SIK PARK  
Table II. Void fraction correlations.  
Correlation  
A
1
1
b
1
1
1
c
1
0.5  
0.67  
d
0
0
0
1
 
 
 
 
        
 
 
 
 
Smith [7]  
1
1
0
√
            
      
 
      (  
)
 
 
Chisholm [17]  
1
1
0
√
     (    
⁄
 
)
 
Spendding & Chen [10]  
Hamersma & Hart [18]  
Tuner & Wallis [19]  
Lockhart & Martinelli [20]  
Thom [21]  
Baroczy [22]  
Madsen [24]  
Chen [25]  
2.22  
0.26  
1
0.28  
1
0.65  
0.67  
0.72  
0.64  
1
0.74  
1
M
0.65  
0.33  
0.4  
0.36  
0.89  
0.65  
1
-0.5  
0.33  
-0.126  
0
0
0.08  
0.07  
0.18  
0.13  
0
0
0.07  
0
1
APRM  
1
0.18  
APA  
0.6  
-0.2  
Petalaz & Aziz [26]  
Table III. Slip ratio correlations.  
Correlation Slip ratio, s  
1
     
 
 
(
)
)
 
 
 
     
Smith [7]  
 
(
 
 
 
 
 
        
 
 
 
 
 
√
            
      
 
      (  
)
      
      
 
Spedding & Chen [10]  
Hamersma & Hart [18]  
    
 
2.22(  
)
( )  
 
 
 
     
     
 
    
 
0.26(  
)
( )  
 
 
 
Kim [6] has currently suggested that the  
slip ratio is the main parameter that could affect  
the diameter effect. In the past, some experimental  
work showed that critical mass flow rate increased  
while reducing the diameter of the throat (Sozzi  
and Sutherland [27], Chun and Park [28], Henry  
[29], Fauske [15]). The increase in the flow rate  
could be explained mainly based on the diameter  
effect. The raise of vaporization may be higher at  
the choking place with a decrease in sub-cooling  
upstream conditions at a very low sub-cooling  
temperature nozzle. It means that the slip ratio  
may increase for low sub-cooling upstream  
conditions. Several correlations of slip ratio were  
reviewed before taking them into account their  
critical flow predictions.  
25  
EVALUATION OF SLIP RATIO CORRELATIONS IN TWO-PHASE FLOW  
By comparing with the experimental  
data, void fraction correlations listed in Table I  
are evaluated. The six selected correlations are  
rewritten in the slip ratio form, as shown in  
Table III. Those slip ratio correlations will be  
evaluated in more detail using different  
pressures for both horizontal [11] and vertical  
[12],[13] tests.  
A. Evaluations using horizontal test data  
Fig. 6. Void fraction vs. quality in comparing with  
the Haywood data at 14.48 MPa (2100 psi) [13].  
Chosen correlations are compared with  
Haywood data for a horizontal test in a high-  
pressure range from 1.72 to 14.5 MPa, as  
shown in Figs. 4, 5, and 6.  
B. Evaluations using vertical test data  
Marchettere [11] and Cook [12]  
performed experiments using the same vertical  
test facility, but at different pressures varied  
from 0.69 to 4.14 MPa. The predictions of  
chosen correlations are compared with the  
vertical test data, as shown in Figs. 7, 8, and 9:  
Even data changes in a high-pressure  
range, the original Smith’s correlation remains  
the best candidate. We can conclude that  
Smith’s correlation with his recommended k =  
0.4 gives the best predictions.  
Fig. 7. Void fraction vs. quality in comparing with  
the experimental data at 0.79 MPa (114.5 psi) [11].  
Fig. 4. Void fraction vs. quality in comparing with  
the Haywood data at 4.14 MPa (600 psi) [13].  
Fig. 5. Void fraction vs. quality in comparing with  
Fig. 8. Void fraction vs. quality in comparing with  
the Haywood data at 8.62 MPa (1250 psi) [13].  
the Experimental data at 1.89 MPa (274.3 psi) [11].  
26  
THANH TRAM TRAN, HYUN-SIK PARK  
The comparison of predictions between  
the chosen correlations and the experimental  
data from Marchettere [11] and Cook [12]  
show that the modified Smith’s correlation  
with k = 0.2, as well as Speeding and Chen  
[10] one, are the best predictions.  
parameter k, which is the ratio between the  
mass liquid in the homogenous mixture and  
the total liquid mass, varies from 0 to 1. If k =  
     
 
 
0, then slip ratio, s= ( )  
, Smith  
 
 
correlation becomes Fauske one, in this case,  
the velocity heads of both liquid and gas are  
 
 
equal,           . If k = 1, then s = 1,  
 
 
    
Smith correlation becomes HEM one,       .  
 
 
However, Smith's correlation was developed  
for the stratified flow with a homogeneous  
mixture phase and a liquid phase. In the  
original HF model, the slip ratio is a constant, s  
=1, which means that the mixture is well  
mixing in a homogeneous equilibrium state. By  
changing the chosen slip ratio correlations in  
the HF model, the predictions of mass flux at  
high quality are quite the same, while they  
become different at low quality.  
Fig. 9. Void fraction vs. quality in comparing with  
the experimental data at 4.24 MPa (614.4 psi) [12].  
From these above comparisons, we  
could conclude that while the original Smith  
correlation with k=0.4 seems to be the best  
correlation for the horizontal test, its  
modification with k=0.2 could be the best  
correlation for the vertical test.  
IV. EVALUATION OF SMITH’S  
CORRELATION  
Fig. 10. Evaluation of critical mass flux for the HF  
model using the experimental data at 0.12 MPa [1].  
In the HF model [1], they developed  
their correlation in assuming that slip ratio  
equals 1. This slip ratio in the original HF  
model is modified by using the chosen slip  
correlations to predict the critical mass flux.  
The results are listed in Figs 10, 11, and 12.  
The evaluation process used data [1] measured  
at 0.12, 1.38, and 2.76 MPa.  
The critical mass flux result of original  
HF is plotted in the continuous black line, and  
its modified one using Smith correlation with  
k = 0.4 is in the red long dash line. It should  
be noted that in Smith's correlation, the  
Fig. 11. Evaluation of critical mass flux for the HF  
model using the experimental data at 1.38 MPa [1].  
27  
EVALUATION OF SLIP RATIO CORRELATIONS IN TWO-PHASE FLOW  
model showed similar results with that  
calculated by using the original HF model. Slip  
ratio correlations, which correlate with critical  
mass flux predictions, were chosen and  
evaluated using both horizontal and vertical  
tests. From this work, we could conclude that  
the original Smith correlation with k=0.4 is the  
best choice for horizontal tests, while the  
modified one with k=0.2 is applicable for the  
vertical test. HF model was developed based  
on the slip ratio of unity. Therefore, we suggest  
modifying this ratio to get a better result for the  
two-phase critical flow simulation. Further data  
evaluation is needed for a wider range of  
pressure for both horizontal and vertical tests  
to get a clear picture of the best option for  
critical flow rate prediction.  
Fig. 12. Evaluation of critical mass flux for the HF  
model using the experimental data at 2.76 MPa [1].  
At a quality higher than 0.1, the results  
at low pressure (Fig. 10) showed a similar  
result for all correlations. However, they  
become different while reducing qualities  
lower than 0.1. At hight pressures, Figs 11 and  
12, the results using Spedding & Chen give a  
bad prediction at very low quality (less than 10-  
3), while this correlation gave as good  
prediction as Smith one for vertical test data as  
can be seen in Figs. 7, 8, and 9.  
NOTATION  
c
Sound velocity ( m/s)  
C Vitural mass (kg)  
D Diameter (m)  
G Mass flux (kg/m2/s )  
Base on the evaluation work for the  
chosen slip correlations, we could conclude  
that the results given by Smith correlation with  
k=0.4 show the best critical mass flux  
prediction. This slip ratio correlation is based  
on simple assumptions for stratified flow. In  
the current computer codes for critical flow  
calculation, HF and TR models are still the  
most popular tools for critical flow predictions.  
HF model, however, keeps using the slip ratio  
of unity. Based on the result of our paper in  
predicting the critical flow rate, the modified  
slip ratio should be considered in the HF to get  
a better prediction.  
h
k
Enthalpy (J/kg)  
liquid mass in the homogeneous mixture  
over total liquid mass  
L Length (m)  
N the partial phase change at the throat  
s
S
x
P
uf Liquid velocity (m/s)  
ug Gas velocity (m/s)  
vf Specific volume of liquid (m3/kg)  
vg Specific volume of gas (m3/kg)  
We Weber number  
Slip ratio, (ug/uf)  
Entropy (J/K)  
Quality  
Presssure (MPa)  
Re Reynolds number  
V. CONCLUSIONS AND FUTURE WORK  
Superscripts  
Due to the limitation in software  
handling, the reproducing model of HF has  
been successfully evaluated. The reproducing  
0
t
Stagnant location  
Throat location  
28  
THANH TRAM TRAN, HYUN-SIK PARK  
[9]. M.A. Woldesemayat, A.J. Ghajar, “Comparison  
g
f
Gas component  
Fluid component  
of void fraction correlations for different flow  
patterns in horizontal and upward vertical  
pipes”, International Journal of Multiphase  
Flow, 33, 347–370, 2007.  
Greeks  
α
γ
λ
η
Void fraction  
[10].P. L. Spedding, J. J. J. Chen, “Holdup in two-  
phase flow”, Int. J. Multiphase Flow, 10, 307-  
339, 1984.  
Isentropic exponent  
The root of characteristic equation  
Critical pressure ratio  
ρf Liquid density (kg/m3)  
ρg Gas density (kg/m3)  
µf Liquid viscosity (Ns/m2)  
µg Gas viscosity (Ns/m2)  
[11].Marchettere, The effect of pressure on boiling  
density in multiple rectangular channels,  
Argonne National Laboratory, Illinois, United  
States, 1956.  
[12].Cook, Boiling density in vertical rectangular  
multichannel sections with natural circulation,  
Argonne National Laboratory, Illinois, United  
States, 1956.  
REFERENCE  
[1]. R. E. Henry, H. K. Fauske, “The two-phase  
critical flow of one-component mixtures in  
nozzles, orifices and short tubes”, Journal of  
heat transfer, 93, 179-187, 1971.  
[13].Haywood, Experimental study on the flow  
conditions and pressure drop of steam-  
water mixture at high pressure in heated  
and unheated tubes, University of  
Cambridge, 1961.  
[2]. J. A. Trap and V. H. Ransom, “A choked-flow  
calculation criterion for nonhomogeneous,  
nonequilibrium, two-phase flows”, Int. J.  
Multiphase Flow, 8, 669-681, 1982.  
[14].E. S. Starkman et al., “Expansion of a very  
low-quality two-phase fluid through  
a
convergent-divergent nozzle”, Journal of Basic  
Engineering, 86, 247-254, 1964.  
[3]. B. D. Chung et al., MARS Code Manual  
Volume V: Models and Correlations,  
KAERI, 2006.  
[15].H. K. Fauske, Contribution to the theory of  
two-phase, one-component critical flow,  
Argonne National Lab, United States, 1962.  
[4]. TRACE, V5.0, Theory manual, Field  
Equations, solution methods, and physical  
models, 2010.  
[16].S.M. Zivi, “Estimation of steady-state steam  
void fraction by means of the principle of  
minimum entropy production”. Trans. ASME,  
J. Heat Transfer, 86, 247–252, 1964.  
[5]. T. T. Tran, Y.S. Kim, H.S. Park, Study on the  
most applicable critical flow models in the  
current system codes, KNS Conference  
2017, Korea.  
[17].D. Chisholm, “Pressure gradients due to  
friction during the flow of evaporating two-  
phase mixtures in smooth tubes and channels”,  
Int. J. Heat Mass Transfer, 16, 347-358, 1973.  
[6]. Y. S. Kim et al., “Overview of geometrical  
effects on the critical flow rate of sub-cooled  
and saturated water”, Annals of Nuclear  
Energy, 76, 12-18, 2015.  
[18].P.J. Hamersma, J. Hart,. “A pressure drop  
correlation for gas/liquid pipe flow with a  
small liquid holdup”. Chem. Eng. Sci.  
42,1187–1196, 1987.  
[7]. S. L. Smith, “Void fractions in two-phase flow:  
a correlation based upon an equal velocity  
head model”, Proc. Inst. Mech. Engrs, 184,  
647-657, Part 1, 1969.  
[19].J.M. Turner, G.B. Wallis, The separate-  
cylinders model of two-phase flow, Paper No.  
[8]. D. Butterworth, “A comparison of some void  
fraction relationships for co-current gas-liquid  
flow”, Int. J. Multiphase Flow, 1, 845-850, 1975.  
NYO-3114-6,  
Thayer’s  
School  
Eng.,  
Dartmouth College, Hanover, NH, USA, 1965.  
29  
                                     
EVALUATION OF SLIP RATIO CORRELATIONS IN TWO-PHASE FLOW  
[20].R.W. Lockhart, R.C. Martinelli, “Proposed [26].N. Petalaz, K. Aziz, A mechanistic model for  
correlation of data for isothermal two-phase,  
two-component flow in pipes”, Chem. Eng.  
Progr. 45, 39–48, 1949.  
stabilized multiphase flow in pipes, a report for  
the members of Stanford reservoir simulation  
industrial affiliates and Stanford project on the  
productivity and injectivity of horizontal wells,  
Stanford University, Palo Alto, CA, 1997.  
[21].J.R.S. Thom, “Prediction of pressure drop  
during forced circulation boiling of water”, Int.  
J. Heat Mass Transfer 7, 709–724, 1964.  
[27].G. L. Sozzi, W. A. Sutherland, “Critical flow  
of saturated and subcooled water at high  
pressure”, Amer. Soc. Mech. Eng. Non-  
Equilibrium Two-Phase Flow Symp., 47, 1975.  
[22].C.J. Baroczy, “A systemic correlation for two-  
phase pressure drop”, Chem. Eng. Progr.  
Symp. Ser. 62, 232–249, 1966.  
[23].A. Premoli, D. Francesco, A. Prima, An  
empirical correlation for evaluating two-phase  
mixture density under adiabatic conditions,  
European Two-Phase Flow Group Meeting,  
Milan, Italy, 1970.  
[28].M. H. Chun and C. K. Park, “An experimental  
investigation of critical flow rates of subcooled  
water through short pipes with small  
diameters”, Int. Comm. Heat Mass Transfer, 23  
(No. 8), 1053-1064, 1996.  
[24].N. Madsen, “A void fraction correlation for  
vertical and horizontal bulk-boiling of water”.  
AIChE J. 21, 607–608, 1975.  
[29].R. E. Henry, Pressure pulse propagation in  
two-phase one and two-component mixtures,  
ANL-7792, Argonne National Laboratory.  
Illinois, United States, 1971.  
[25].J.J.J. Chen, “A further examination of void-  
fraction in the annular two-phase flow”, Int. J.  
Heat Mass Transfer 29, 1760–1763, 1986.  